General Ecology presents
data from testing specifically selected to demonstrate
product effectiveness in removing those contaminants
most frequently encountered in water supplies.
Please note that all
General Ecology test results represent performance
using actual contaminants, not substitute surrogates
which some companies submit.
This Performance Data Sheet shows some of the
removal capabilities of Seagull IV Water Purifiers.
It is recommended that before purchasing a water
treatment unit you have your water supply tested
to determine your actual water treatment needs.
Seagull IV® Drinking
Water Purifiers
Product Brand Name:
- Seagull
IV X-1 Drinking Water Purification System
- Configuration
B,F,D,P, FP,KF
- Seagull
IV X-2 Drinking Water Purification System
- Configuration B,KB,KF
- Seagull
IV X-6 Drinking Water Purification System
Manufacturer
: Made in USA by
General Ecology, Inc.
| Operating
Conditions: |
|
Seagull
IV X-1 purifier |
Seagull
IV X-2 purifier |
Seagull
IV X-6 purifier |
| Housing |
Stainless
Steel Housing |
| Cartridge |
RS-1SG |
RS-2SG |
RS-6SG module |
| Flow Rate
per minute gallons (litres) |
1 gpm (3.8
lpm) |
2 gpm (7.6
lpm) |
6 gpm (23
lpm) |
| Average Capacity
gallons (litres) |
1000 gal.
(3800 ltr.) |
2000 gal.
(7600 ltr.) |
6000 gal.
(23000 ltr.) |
| Operating
Pressure (min psi/ max psi) |
30/
125 |
| Particle
Retention (microns) |
.1
nominal
.4 absolute |
| Temperature
Range F° (C°) |
32°
- 145° (0° to 62°) - do not freeze |
| *Contact
us for additional information on specifications
or dimensions. *Average rated life span,
flow rate are based on tested waters, actual
capacity may vary depending on quality of
water source. * Intended for cold water
use. Intended for use with Seagull IV water
purifiers. |
Test conditions :
All tests were conducted under standard operating
conditions as previously stated for rated capacity
of cartridge/module. The data are based on documented
results from specific testing and are generally
regarded as indicative of the effectiveness to
be expected but are not specific claims of performance.
Contaminant
Tested
Organic Chemicals |
Influent |
Effluent |
Detection
Level
ND - None Detected |
MCL+ |
| 1,1 Dichloroethane |
10 ppb |
ND |
2 ppb |
-- |
| 1,1,2-Trichloroethane |
20 ppb |
ND |
2 ppb |
5 ppb* |
| 1,2-Dibromomethane
(EDB) |
1.9 ppb |
ND |
.2 ppb |
5 ppb |
| 1,4-Dichlorobenzene |
73 ppb |
ND |
NSF Standard
53 |
5 ppb++ |
| 2,4,5-TP
(Silvex) |
30.6 ppb |
ND |
.05 ppb |
10 ppb |
| 2,4-D |
338 ppb |
ND |
1 ppb |
70 ppb |
| Aldicarb
(Temik) |
228 ppb |
ND |
1 ppb |
7 ppb++ |
| Carbon Tetrachloride |
20 ppb |
0.6 ppb |
|
5 ppb |
| Chlordane |
50 ppb |
ND |
1 ppb |
20 ppb |
| Chlorine
Residual |
500 ppb |
ND |
50 ppb |
2.5 ppm (not
an MCL) |
| Chloroform |
300 ppb |
ND |
1 ppb |
-- |
| Dichlorethane |
9.8 ppb |
0.882 ppb |
-- |
5 ppb |
| Diisopropyl
ether |
89 ppb |
ND |
-- |
-- |
| Hexachlorobenzene |
10 ppb |
ND |
.1 ppb |
.1 ppb |
| Methoxychlor |
114 ppb |
<3 ppb |
2 ppb |
40 ppb ** |
| P-chlorobenzene |
10 ppb |
ND |
.1 ppb |
5 ppb proposed
* |
| PCB |
0.05 ppb |
ND |
.01 ppb |
-- |
| Tetrachlorethylene
(PCE) |
73 ppb |
ND |
NSF Standard
53 |
5 ppb |
| Trichloroethylene
(TCE) |
328 ppb |
ND |
NSF Standard
53 |
5 ppb |
| Trihalomethane
Total |
92 ppb |
ND |
1ppb |
100 ppb** |
Contaminant
Tested
Microbiological |
Influent
(colonies/100ml) |
Effluent
(colonies/100ml) |
Detection
Level
(colonies/100ml)
ND - None Detected |
MCL+
(colonies/100ml) |
| Campylobacter
jejuni |
1.6-3.0 x
107 |
ND |
10 |
-- |
| Cryptosporidia |
1.8 x 103 |
ND |
1 |
-- |
| Escherichia
coli |
107 |
ND |
1 |
0/100 ml |
| Fecal Coliform |
103 |
ND |
1 |
0/100 ml |
| Giardia lamblia |
1.13 x 105+++ |
ND |
1 |
-- |
| Klebsiella
terrigena |
4.64 x 108 |
ND |
3 |
-- |
| Listeria
monocytogenes |
2.2-2.8 x
107 |
ND |
10 |
-- |
| Polio Virus/Rota
virus |
2.39 x 106 |
ND |
150 |
-- |
| Pseudomonas
aerigompsa§ |
103 |
ND |
1 |
-- |
| Salmonella
typhi§ |
105 |
ND |
1 |
0/100 ml |
| Staphylococcus
aureus§ |
106 |
ND |
1 |
-- |
| Streptococcus
foecalis§ |
105 |
ND |
1 |
-- |
| Vibrio cholerae
inaba§ |
106 |
ND |
1 |
-- |
| Vibrio cholerae
ogawa§ |
106 |
ND |
1 |
-- |
| Yersinia
enterocolitica |
2.0-2.8 x
105 |
ND |
10 |
-- |
Contaminant
Tested
Metals |
Influent |
Effluent |
Detection
Level
ND - None Detected |
MCL+ |
| Iron± |
.8 mg/l |
.06 mg/l |
-- |
-- |
| Lead¥ |
90 ppb |
ND |
2 ppb |
15 ppb |
|
| Aesthetics |
Original
Well Water |
Tested
Water |
|
|
| Color |
20 |
0 |
-- |
-- |
| Hardness |
72 mg/L |
66 mg/l |
-- |
-- |
| Odor |
abnormal |
normal |
-- |
-- |
| Taste |
abnormal |
normal |
-- |
-- |
| Turbidity |
2 |
0 |
-- |
1.0 |
Aesthetic water quality
improvement :
Seagull®IV Drinking Water
Purification Systems
also remove the following, which some individuals
may find offensive in drinking water: • Chlorine
• Foul Tastes • Color • Foul Odors • Turbidity
| Contaminant
Leached |
Testing
Protocol |
Result |
Detection
Level
ND - None Detected |
| 1,1,1-Trichloroethane |
NSF Standard
53 |
ND |
1 ppb |
| 1,1 Dichloroethylene |
NSF Standard
53 |
ND |
1 ppb |
| 1,2-Dichloroethylene |
NSF Standard
53 |
ND |
1 ppb |
| Benzene |
NSF Standard
53 |
ND |
1 ppb |
| Bromodichloromethane |
NSF Standard
53 |
ND |
2 ppb |
| Bromoform |
NSF Standard
53 |
ND |
4 ppb |
| Cadmium |
NSF Standard
53 |
ND |
2 ppb |
| Carbontetrachloride |
NSF Standard
53 |
ND |
1 ppb |
| Chloroform |
NSF Standard
53 |
ND |
2 ppb |
| Chromium |
NSF Standard
53 |
ND |
4 ppb |
| Dibromochloromethane |
NSF Standard
53 |
ND |
4 ppb |
| Lead |
NSF Standard
53 |
ND |
1 ppb |
| Mercury |
NSF Standard
53 |
ND |
.2 ppb |
| Methylene
Chloride |
NSF Standard
53 |
ND |
1 ppb |
| Phenols |
NSF Standard
53 |
ND |
10 ppb |
| Tetrachloroethylene |
NSF Standard
53 |
ND |
1 ppb |
| TOC |
NSF Standard
53 |
ND |
500 ppb |
| Trichloroethylene |
NSF Standard
53 |
ND |
1 ppb |
| Trihalomethane
Total |
NSF Standard
53 |
ND |
2 ppb |
| Vinyl Chloride |
NSF Standard
53 |
ND |
1 ppb |
Legend :
+ Maximum Contaminant Level of Federal Standards
shown unless a more rigorous standard is indicated.
++ New York Maximum Contaminant Level is more
rigorous than Federal level.
+++ Total per 500 gallons.
§ Sampled at less than rated capacity.
± Iron will tend to shorten cartridge life.
¥ Cartridge used in the test was 1 year 2 months
old.
* Journal AWWA, February 1992.
** Water Technology, August 1991.
Note: Seagull®IV purifiers do not remove beneficial
dissolved salts and essential minerals.
Various Federal, State and Local regulations may
become known or change and affect distribution
and presentation of performance claims. All health
claims not in compliance with local or state laws
are hereby withdrawn.
Installation instructions
:
Seagull®IV Drinking Water Purification System
X-1/X-2 series are designed to connect
to the cold water supply and also can connect
directly to the main faucet or an auxiliary faucet
depending upon configuration selection. Seagull®IV
Drinking Water Purification System X-6 series
installs directly into fresh water supply line.
Please see the Installation And Product Use Instructions
for diagrams and detailed step-by-step directions.
Customer Satisfaction/Money
Back Guarantee :
General Ecology, Inc. stands behind the quality
and effectiveness of our Seagull®IV Drinking Water
Purification Systems If you are not
fully satisfied with your system, simply return
it to the point of purchase within 30 days, undamaged,
for a FULL REFUND
of purchase price. |