Seagull®
IV Water Purifiers- Product Data Sheet 
for United States Standards
General Ecology presents data from testing specifically
selected to demonstrate product effectiveness in removing those contaminants
most frequently encountered in water supplies. Please
note that all General Ecology test results represent performance using actual
contaminants, not substitute surrogates.
This Performance Data Sheet shows some of the removal capabilities of Seagull
IV Water Purifiers. It is recommended that before purchasing a water treatment
unit you have your water supply tested to determine your actual water treatment
needs.
Seagull IV® Drinking Water Purifiers
Product Brand Name:
- Seagull IV X-1 Drinking Water
Purification System - Configuration B,F,P,KF
- Seagull IV X-2 Drinking Water
Purification System - Configuration B,KB,KF
- Seagull IV X-6 Drinking Water
Purification System
Operating
Conditions: |
|
Seagull IV X-1 purifier |
Seagull IV X-2 purifier |
Seagull IV X-6 purifier |
Housing Material |
Stainless Steel Housing |
Cartridge |
RS-1SG |
RS-2SG |
RS-6SG |
Flow Rate @ 30 psi - gmp (lpm) |
1 gpm (3.8 lpm) |
2 gpm (7.6 lpm) |
6 gpm (23 lpm) |
Average Capacity gallons (litres) |
1000 gal. (3800 ltr.) |
2000 gal. (7600 ltr.) |
6000 gal. (23000 ltr.) |
pH min/max |
5/9 |
Particle Retention (microns) |
.1 nominal
.4 absolute |
Temperature Range F° (C°) |
33° - 100° (1° to 38°) -
do not freeze |
- No electricity is required.
- Flow rate and capacity will depend on operation conditions and source water characteristics.
- The cartridge should be replaced annually, when the flow rate drops to an inconvenient level or if tastes and odours should become evident.
- Intended for cold water use.
- Intended for fresh water use only. Does not desalinate.
|
Test conditions : All tests were conducted
under standard operating conditions as previously stated for rated capacity
of cartridge.
Performance Notice: These data are based on documented results from specific
testing and are generally regarded as indicative of the effectiveness to
be expected but are not specific claims of performance. Performance may vary due to water characteristics and system operating conditions.
Contaminant Tested
Organic Chemicals |
Influent |
Effluent |
Detection Level
ND - None Detected |
MCL+ |
1,1,2-Trichloroethane |
20 ppb |
ND |
2 ppb |
5 ppb* |
1,2-Dibromomethane (EDB) |
1.9 ppb |
ND |
.2 ppb |
5 ppb |
1,4-Dichlorobenzene |
73 ppb |
ND |
NSF Standard 53 |
5 ppb++ |
2,4,5-TP (Silvex) |
30.6 ppb |
ND |
.05 ppb |
10 ppb |
2,4-D |
338 ppb |
ND |
1 ppb |
70 ppb |
Aldicarb (Temik) |
228 ppb |
ND |
1 ppb |
7 ppb++ |
Carbon Tetrachloride |
20 ppb |
0.6 ppb |
|
5 ppb |
Chlordane |
50 ppb |
ND |
1 ppb |
20 ppb |
Chlorine Residual |
500 ppb |
ND |
50 ppb |
2.5 ppm (not an MCL) |
Chloroform |
300 ppb |
ND |
1 ppb |
-- |
Methoxychlor |
114 ppb |
<3 ppb |
2 ppb |
40 ppb ** |
P-chlorobenzene |
10 ppb |
ND |
.1 ppb |
5 ppb proposed * |
PCB |
0.05 ppb |
ND |
.01 ppb |
-- |
Tetrachlorethylene (PCE) |
73 ppb |
ND |
NSF Standard 53 |
5 ppb |
Trichloroethylene (TCE) |
328 ppb |
ND |
NSF Standard 53 |
5 ppb |
Trihalomethane Total |
92 ppb |
ND |
1ppb |
100 ppb** |
Contaminant Tested
Microbiological |
Influent
(colonies/100ml) |
Effluent
(colonies/100ml) |
Detection Level
(colonies/100ml)
ND - None Detected |
MCL+
(colonies/100ml) |
Campylobacter jejuni |
1.6-3.0 x 107 |
ND |
10 |
-- |
Cryptosporidia |
1.8 x 103 |
ND |
1 |
-- |
Escherichia coli |
107 |
ND |
1 |
0/100 ml |
Escherichia coli 0157:H7 |
107 |
ND |
10 |
0/100 ml |
Fecal Coliform |
103 |
ND |
1 |
0/100 ml |
Giardia lamblia |
1.13 x 105+++ |
ND |
1 |
-- |
Listeria monocytogenes |
2.2-2.8 x 107 |
ND |
10 |
-- |
Polio Virus/Rota virus |
2.2-2.8 x 107 |
ND-320pfu |
11pfu |
-- |
Pseudomonas aerigompsa§ |
103 |
ND |
1 |
-- |
Salmonella typhi§ |
105 |
ND |
1 |
0/100 ml |
Yersinia enterocolitica |
2.0-2.8 x 105 |
ND |
10 |
-- |
Contaminant Filtered
Metals |
Influent |
Effluent |
Detection Level
ND - None Detected |
MCL+ |
Aesthetics |
Original Well Water |
Tested Filtered Water |
|
|
Colour |
20 |
0 |
-- |
-- |
Hardness |
72 mg/L |
66 mg/L |
-- |
-- |
Odour |
abnormal |
normal |
-- |
-- |
Taste |
abnormal |
normal |
-- |
-- |
Turbidity |
2 |
0 |
-- |
-- |
Color |
20 |
0 |
-- |
-- |
Extraction Data: Leaching Tests Comply with NSF Standard 53
Contaminant Leached |
Testing Protocol |
Result |
Detection Level |
Systems have been evaluated, tested and comply with NSF/ANSI Standard 53-2010 requirements for extraction of volatiles, semi-volatiles and metal.
|
Legend :
+ Maximum Contaminant Level of Federal Standards shown unless a more
rigorous standard is indicated.
++ New York Maximum Contaminant Level is more rigorous than Federal level.
+++ Total per 500 gallons.
§ Sampled at less than rated capacity.
* Journal AWWA, February 1992.
** Water Technology, August 1991.
Note: Seagull®IV purifiers do not remove dissolved salts and
minerals.
Various Federal, Provincial and Local regulations may become known or change
and affect distribution and presentation of performance claims. All health