General Ecology presents data from testing specifically selected to demonstrate product effectiveness in removing those contaminants most frequently encountered in water supplies. Please note that all General Ecology test results represent performance using actual contaminants, not substitute surrogates.

This Performance Data Sheet shows some of the removal capabilities of Seagull IV Water Purifiers. It is recommended that before purchasing a water treatment unit you have your water supply tested to determine your actual water treatment needs.

Seagull IV® Drinking Water Purifiers

Product Brand Name:
  • Seagull IV X-1 Drinking Water Purification System - Configuration B,F,P,KF
  • Seagull IV X-2 Drinking Water Purification System - Configuration B,KB,KF
  • Seagull IV X-6 Drinking Water Purification System

Operating Conditions:
  Seagull IV X-1 purifier Seagull IV X-2 purifier Seagull IV X-6 purifier
Housing Material Stainless Steel Housing
Cartridge RS-1SG RS-2SG RS-6SG
Flow Rate @ 30 psi - gmp (lpm) 1 gpm (3.8 lpm) 2 gpm (7.6 lpm) 6 gpm (23 lpm)
Average Capacity gallons (litres) 1000 gal. (3800 ltr.) 2000 gal. (7600 ltr.) 6000 gal. (23000 ltr.)
pH min/max 5/9
Particle Retention (microns) .1 nominal
.4 absolute
Temperature Range F° (C°) 33° - 100° (1° to 38°) - do not freeze
  • No electricity is required.
  • Flow rate and capacity will depend on operation conditions and source water characteristics.
  • The cartridge should be replaced annually, when the flow rate drops to an inconvenient level or if tastes and odours should become evident.
  • Intended for cold water use.
  • Intended for fresh water use only. Does not desalinate.

Test conditions : All tests were conducted under standard operating conditions as previously stated for rated capacity of cartridge.

Performance Notice: These data are based on documented results from specific testing and are generally regarded as indicative of the effectiveness to be expected but are not specific claims of performance. Performance may vary due to water characteristics and system operating conditions.

Contaminant Tested

Organic Chemicals
Influent Effluent Detection Level

ND - None Detected
MCL+
1,1,2-Trichloroethane 20 ppb ND 2 ppb 5 ppb*
1,2-Dibromomethane (EDB) 1.9 ppb ND .2 ppb 5 ppb
1,4-Dichlorobenzene 73 ppb ND NSF Standard 53 5 ppb++
2,4,5-TP (Silvex) 30.6 ppb ND .05 ppb 10 ppb
2,4-D 338 ppb ND 1 ppb 70 ppb
Aldicarb (Temik) 228 ppb ND 1 ppb 7 ppb++
Carbon Tetrachloride 20 ppb 0.6 ppb   5 ppb
Chlordane 50 ppb ND 1 ppb 20 ppb
Chlorine Residual 500 ppb ND 50 ppb 2.5 ppm (not an MCL)
Chloroform 300 ppb ND 1 ppb --
Methoxychlor 114 ppb <3 ppb 2 ppb 40 ppb **
P-chlorobenzene 10 ppb ND .1 ppb 5 ppb proposed *
PCB 0.05 ppb ND .01 ppb --
Tetrachlorethylene (PCE) 73 ppb ND NSF Standard 53 5 ppb
Trichloroethylene (TCE) 328 ppb ND NSF Standard 53 5 ppb
Trihalomethane Total 92 ppb ND 1ppb 100 ppb**


Contaminant Tested
Microbiological
Influent
(colonies/100ml)
Effluent
(colonies/100ml)
Detection Level
(colonies/100ml)

ND - None Detected
MCL+
(colonies/100ml)
Campylobacter jejuni 1.6-3.0 x 107 ND 10 --
Cryptosporidia 1.8 x 103 ND 1 --
Escherichia coli 107 ND 1 0/100 ml
Escherichia coli 0157:H7 107 ND 10 0/100 ml
Fecal Coliform 103 ND 1 0/100 ml
Giardia lamblia 1.13 x 105+++ ND 1 --
Listeria monocytogenes 2.2-2.8 x 107 ND 10 --
Polio Virus/Rota virus 2.2-2.8 x 107 ND-320pfu 11pfu --
Pseudomonas aerigompsa§ 103 ND 1 --
Salmonella typhi§ 105 ND 1 0/100 ml
Yersinia enterocolitica 2.0-2.8 x 105 ND 10 --


Contaminant Filtered

Metals
Influent Effluent Detection Level

ND - None Detected
MCL+
Aesthetics Original Well Water Tested Filtered Water    
Colour 20 0 -- --
Hardness 72 mg/L 66 mg/L -- --
Odour abnormal normal -- --
Taste abnormal normal -- --
Turbidity 2 0 -- --
Color 20 0 -- --

Extraction Data: Leaching Tests Comply with NSF Standard 53

Contaminant Leached Testing Protocol Result Detection Level

 

Systems have been evaluated, tested and comply with NSF/ANSI Standard 53-2010 requirements for extraction of volatiles, semi-volatiles and metal.

 

Legend :
+ Maximum Contaminant Level of Federal Standards shown unless a more rigorous standard is indicated.
++ New York Maximum Contaminant Level is more rigorous than Federal level.
+++ Total per 500 gallons.
§ Sampled at less than rated capacity.
* Journal AWWA, February 1992.
** Water Technology, August 1991.

Note: Seagull®IV purifiers do not remove dissolved salts and minerals. Various Federal, Provincial and Local regulations may become known or change and affect distribution and presentation of performance claims. All health claims not in compliance with local, provindial or federal laws are hereby withdrawn.